Abstract
Thousands of sites are contaminated with both heavy metals and organic compounds and these sites pose a major threat to public health and the environment. Previous studies have shown that electrokinetic remediation has potential to remove heavy metals and organic compounds when they exist individually in low permeability soils. This paper presents the feasibility of using cyclodextrins in electrokinetic remediation for the simultaneous removal of heavy metals and polycyclic aromatic hydrocarbons (PAHs) from low permeability soils. Kaolin was selected as a model low permeability soil and it was spiked with phenanthrene as well as nickel at concentrations of 500 mg kg −1 each to simulate typical mixed field contamination. Bench-scale electrokinetic experiments were conducted using hydroxypropyl β-cyclodextrin (HPCD) at low (1%) and high (10%) concentrations and using deionized water in control test. A periodic voltage gradient of 2 VDC cm −1 (with 5 d on and 2 d off) was applied to all the tests, and 0.01 M NaOH was added during the experiments to maintain neutral pH conditions at anode. In all tests, nickel migrated as Ni 2+ ions towards the cathode and most of it was precipitated as Ni(OH) 2 within the soil close to the cathode due to high pH condition generated by electrolysis reaction. The solubility of phenanthrene in the flushing solution and the amount of electroosmotic flow controlled the migration and removal of phenanthrene in all the tests. Even though high flow was generated in tests using deionized water and 1% HPCD, migration and removal of phenanthrene was low due to low solubility of phenanthrene in these solutions. The test with 10% HPCD solution showed higher solubility of phenanthrene which caused it migrate towards the cathode, but further migration and removal was retarded due to reduced electric current and electroosmotic flow. Approximately one pore volume of flushing resulted in approximately 50% removal of phenanthrene from the soil near the anode. Sustained higher electroosmotic flow with higher concentration cyclodextrin and maintaining low soil pH near cathode should be investigated to increase removal efficiency of both phenanthrene and nickel.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.