Abstract
Simple SummaryTumors increase their glucose and choline uptake to support growth. These properties are employed to detect and identify tumors in the body by imaging the uptake of radio-isotope analogs of these compounds. In this study we show that deuterium metabolic imaging (DMI) (a new MRI method to image metabolites using non-radioactive labeling with deuterium) can image choline uptake in tumors. Furthermore, we demonstrate that DMI can image the tumor uptake of choline and glucose (and additionally its metabolic conversion) simultaneously, in contrast to radio-isotope imaging, which only assesses the uptake of one radio-isotope labeled compound at a time. For these reasons (and also because DMI is relatively simple and can be combined with other MR methods), it is a promising modality for a more specific tumor characterization than by separate imaging of the uptake of radio-isotope labeled glucose or choline.Increased glucose and choline uptake are hallmarks of cancer. We investigated whether the uptake and conversion of [2H9]choline alone and together with that of [6,6′-2H2]glucose can be assessed in tumors via deuterium metabolic imaging (DMI) after administering these compounds. Therefore, tumors with human renal carcinoma cells were grown subcutaneously in mice. Isoflurane anesthetized mice were IV infused in the MR magnet for ~20 s with ~0.2 mL solutions containing either [2H9]choline (0.05 g/kg) alone or together with [6,6′-2H2]glucose (1.3 g/kg). 2H MR was performed on a 11.7T MR system with a home-built 2H/1H coil using a 90° excitation pulse and 400 ms repetition time. 3D DMI was recorded at high resolution (2 × 2 × 2 mm) in 37 min or at low resolution (3.7 × 3.7 × 3.7 mm) in 2:24 min. Absolute tissue concentrations were calculated assuming natural deuterated water [HOD] = 13.7 mM. Within 5 min after [2H9]choline infusion, its signal appeared in tumor spectra representing a concentration increase to 0.3–1.2 mM, which then slowly decreased or remained constant over 100 min. In plasma, [2H9]choline disappeared within 15 min post-infusion, implying that its signal arises from tumor tissue and not from blood. After infusing a mixture of [2H9]choline and [6,6′-2H2]glucose, their signals were observed separately in tumor 2H spectra. Over time, the [2H9]choline signal broadened, possibly due to conversion to other choline compounds, [[6,6′-2H2]glucose] declined, [HOD] increased and a lactate signal appeared, reflecting glycolysis. Metabolic maps of 2H compounds, reconstructed from high resolution DMIs, showed their spatial tumor accumulation. As choline infusion and glucose DMI is feasible in patients, their simultaneous detection has clinical potential for tumor characterization.
Highlights
Enhanced glucose uptake is a hallmark of malignant tumors
The 2H magnetic resonance (MR) spectrum recorded with the 2H coil, without further localization, before the infusion only showed a signal for natural abundance HOD (Figure 1B)
In this study, we demonstrate that deuterium metabolic imaging (DMI) of [2H9]choline uptake in tumors subcutaneously growing in the mice is feasible
Summary
Enhanced glucose uptake is a hallmark of malignant tumors For diagnostic purposes, this is traditionally assessed via PET using the glucose analog 18Fluordeoxyglucose (FDG) [1]. The hyper-polarization of 13C nuclei in labeled compounds considerably improves the signal-to-noise ratio (SNR) of their signals. Applying these compounds to the body enables imaging of metabolic processes otherwise not detectable by MR, but this method is limited by a short time window of visibility. This short time window affects glucose in particular due to short T1 relaxation times of the 13C nuclei in this molecule [5,6]. The method may be rather non-specific due to various interactions in which these protons are involved and it gives no direct view on glucose catabolism [7]
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.