Abstract

A high-performance chromatography-photodiode array detection (HPLC-PAD) method has been developed and validated for the identification and quantification of ten phthalates; diethyl phthalate (DEP), diallyl phthalate (DAP), benzyl butyl phthalate (BBP), di-n-butyl phthalate (DBP), dihexyl phthalate (DHP), dicyclohexyl phthalate (DCHP), di-2-ethylhexyl phthalate (DEHP), di-n-octyl phthalate (DOP), diisononyl phthalate (DINP) and diisodecyl phthalate (DIDP) in children’s PVC toys. The phthalates were extracted from PVC toy sample using ultrasonic extraction with methanol. Quantification analysis was achieved by gradient elution mode using reversed-phase ODS-4 C18 column with PAD detection at 226 nm. The method has been validated for (BBP, DOP, DINP, and DIDP) and (DEP, DAP, DBP, DCHP, DHP, and DEHP) in the concentration range of 1–100 and 2–200 mg L−1, respectively. The accuracy determined as recovery were 82.85–107.40% with RSD values at 0.8–4.2%. The limits of detection for (DEP, DAP, BBP, DBP, DCHP, DHP, DEHP, DOP, DINP, and DIDP) were 0.02, 0.04, 0.01, 0.03, 0.02, 0.03, 0.03, 0.01, 0.08, and 0.10 mg L−1, respectively.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.