Abstract

Neonicotinoids (NEOs) are used for the phytosanitary treatment of Mentha Spicata.L crops, and this practice requires precise control of these harmful substances at very low concentrations. The objective of this study is to apply an approach allowing simultaneously validation and evaluation of measurement uncertainty based on total error methodology, in order to accurately quantify the presence of two NEOs in Mentha Spicata.L utilizing a Quick, Easy, Cheap, Effective, Rugged, and Safe (QuEChERS)-LC-MS/MS methodology. The quantification of imidacloprid and acetamiprid employing a QuEChERS extraction method, coupled with LC-MS/MS, ensuring the accuracy of the analytical method and managing the risks associated with its routine use.A complete and exhaustive validation approach based on the "β-content, γ-confidence" tolerance interval was used for the uncertainty assessment, using the generalized pivot quantity (GPQ) concept and Monte Carlo simulation, which avoids the need for additional data while achieving intermediate precision for each concentration level within predetermined acceptable limits. The validation procedure is based on the choice of a quadratic model for the two NEOs, allowing the validation of acetamiprid and imidacloprid by LC-MS/MS assay within the range of working concentration. The flexibility of the uncertainty profile intervals was demonstrated with a variation in β-content values (66.7, 80, and 90%) and risk values (10 and 5%), which remained within the acceptability limits of 20%, and the relative expanded uncertainty did not exceed 15 and 11%. A QuEChERS-LC-MS/MS method for the analysis of two NEOs has been successfully fully validated using the uncertainty profile strategy. Implementation of an overall validation strategy, which involves both the validation and uncertainty assessment known as the uncertainty profile, for the quantification of two important NEOs in Mentha Spicata.L using QuEChERS-LC-MS/MS. This qualimetric approach has been conducted by computing the measurement uncertainty of the method utilizing data from analytical validation under conditions of intermediate precision at each level of concentration without additional effort. After that we have demonstrated the flexibility of this strategy for the LC-MS/MS quantification of acetamiprid and imidacloprid, using a decision tool that enables the choice and modification of β-content and γ-confidence values.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call