Abstract

Biomedical research in areas such as metabolic disorders, neuromodulatory, and immunomodulatory conditions involves lipid metabolism and demands a reliable and inexpensive method for quantification of short chain fatty acids (SCFAs). We report a GC–MS method for analysis of all straight-chain and branched-chain SCFAs using pentafluorobenzyl bromide (PFBBr) as derivatization reagent. We optimized the derivatization and GC–MS conditions using a mixture containing all eight SCFA standards, i.e., five straight-chain and three branched-chain SCFAs. The optimal derivatization conditions were derivatization time 90 min, temperature 60 °C, pH 7, and (CH3)2CO:H2O ratio 2:1 (v:v). Comparing the performance of different GC column configurations, a 30 m DB-225ms hyphenated with a 30 m DB-5ms column in tandem showed the best separation of SCFAs. Using the optimized experiment conditions, we simultaneously detected all SCFAs with much improved detection limit, 0.244–0.977 μM. We further applied the developed method to measure the SCFAs in mouse feces and all SCFAs were successfully quantified. The recovery rates of the eight SCFAs ranged from 55.7% to 97.9%.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.