Abstract

An effective extraction procedure based on the complexation of Cu 2+ , Cd 2+ , and Ni 2+ with dithizone and extraction of these complexes by Tergitol NP-7 surfactant was developed. Micelle mediated extraction parameters such as pH, ligand and surfactant concentration, incubation time and temperature were investigated and optimized. Effects of external and internal interfering ions, linear dynamic range, detection and quantitation limits were examined and determined under optimal conditions. Detection limits were found as 0.5, 1.8 and 2.0 mg L -1 for Cu 2+ , Ni 2+ and Cd 2+ , respectively. Linear dynamic range values were between 0.125-2, 0.125-2.5 and 0.05-1.4 μg mL -1 for Cu 2+ , Ni 2+ and Cd 2+ ions, respectively. Applicability, accuracy and precision of the method were checked with standard reference materials and real sample analyses by analyte addition technique. Finally, optimized method was applied to determine Cu 2+ , Ni 2+ and Cd 2+ contents of standard reference materials, mushrooms and water samples. Quantitative and accurate results were obtained from the analysis of standard reference materials and real samples.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call