Abstract

Using a transient calorimetric technique, the specific heat and total hemispherical emissivity of chromel and alumel were measured simultaneously in the temperature range 360–760 K. Two types of specimens for each material were prepared. To obtain reliable experimental values of specific heat and total hemispherical emissivity, an expression for the time history of the temperature of the specimens was developed; this expression is accurate over the whole temperature range. An error analysis is made and the uncertainty (the total error) in the values of specific heat and total hemispherical emissivity is estimated to be 3.1% for the well-designed specimens.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.