Abstract

A sensor using a single distributed-feedback (DFB) diode laser at 1.57 μm for the simultaneous measurement of CO(2) and CO concentration at elevated temperatures is developed. A proper line pair near 6361.250 and 6361.344 cm(-1) is chosen based on absorption strength, separation of the two lines, and isolation from interference of neighboring transitions of the major combustion gases. The concentrations of CO(2) and CO are inferred from their wavelength modulation spectroscopy (WMS) 1ƒ-normalized absorption-based WMS-2ƒ signal peak heights. The CO(2) and CO concentration measurements are within 3.3% and 5% of the expected values over the full temperature range.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call