Abstract

We present a method to simultaneously determine water temperature and salinity, which uses a pulsed excitation laser and a three-channel Raman spectrometer. The method relies on the systematic dependence of the Raman OH stretching band on temperature and salinity, and is compatible with LiDAR techniques. We have measured the variation of the OH stretching band in two seawater samples and a NaCl solution, and constructed a linear mapping between signal ratios derived from the three spectral channels and the temperature and salinity of each sample. For the natural seawater this approach has been determined by cross-validation to have a predictive accuracy of ±1.6 PSU and ±0.5 °C.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.