Abstract
In this paper, a novel platform for simultaneous measurement of relative humidity (RH) and temperature using dual Fabry–Perot interferometers (FPIs) based on C-shaped fiber was demonstrated. The sensor was composed by splicing two sections of C-shaped fiber between single mode fiber (SMF). Polydimethylsiloxane (PDMS) and polyvinyl alcohol (PVA) are filled in the two sections of C-shaped fibers to increase sensitivity to temperature and RH. This is the first demonstration that solid polymer materials can be added to the C-shaped fiber interferometers for sensing. In our experiment, RH sensitivities of -0.128 nm/%RH and 0.038 nm/%RH in the range of 20%RH to 45%RH, and temperature sensitivities of 0.022 nm/°C and -0.722 nm/°C in the temperature range of 15 °C to 45°C, were acquired for dual FPIs, respectively. We verified that it is possible to use the sensitivity matrix method to measure two parameters simultaneously. In addition, it has the benefits of simple structure, excellent stability and high sensitivity, and has a broad application prospect in agriculture, food processing and environmental measurement.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.