Abstract

ObjectivePatellofemoral kinematics and contact mechanics are important measurements for the assessment of patellofemoral joint (PFJ) problems. Simultaneously measuring PFJ contact pressures and kinematics is a challenging task. The purpose of this study was to simultaneously measure the kinematics and mean/peak contact pressures in the PFJs of cadaveric knees.MethodsThis was a comparative study performed on fresh cadaveric knees. The kinematic data was acquired for nine cadaveric knees using an optical tracking system. Data about the contact pressure and contact area in the PFJ was obtained at knee flexion angles of 0°, 30°, 60°, 90°, and 120° using a pressure sensor. Intraclass correlation coefficients (ICCs) and minimal detectable differences (MDDs) of six degrees of freedom (6 DOF) in the PFJs were calculated. ICCs and the MDDs of contact pressure, peak pressure, and contact area in the PFJs were also analyzed. We also compared the kinematics of the cadaveric knees before and after the insertion of the pressure sensor.ResultsAll ICC values of 6 DOF in the PFJs were found to be greater than or equal to 0.924. Regarding medial–lateral rotation, the patellar showed a simplified movement pattern that demonstrated progressive lateral rotation of 4.8° ± 3.4° at 120° of knee flexion. While for patellar tilting, the patella showed medial tilting that peaked at 7.2 ± 2.5° at 30° of knee flexion. Whereas no significant differences in PFJ kinematics were found between with and without the placement of the pressure sensor at all knee flexions (P > 0.05). Most of the ICC values for contact pressure, peak contact pressure, and contact area ranged from 0.8 to 0.9. The MDDs for rotational displacement were 0.9° and 0.6 mm for translational displacement. No statistical differences in patellar kinematics were found before and after the insertion of the pressure sensor.ConclusionsThe setup in the present study enables researchers to simultaneously and synchronously collect real‐time PFJ kinematics and tibiofemoral joint (TFJ) biomechanical kinematic data with high reliability. The low MDDs enabled the researchers to obtain an accurate interpretation of the kinematic and contact mechanics measurement using the experimental setting used in the present study.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call