Abstract

Accurate measurements of NH3 and NO are essential for controlling NOx emissions from coal-fired power plants, reducing ammonia slip, and improving the efficiency of selective catalytic reduction (SCR) operation. We propose a method for measuring NH3 and NO concentrations based on machine learning algorithms to address the challenges posed by overlapping interference of CO2 and H2O spectral lines in flue gas. Our approach introduces a novel method for acquiring mixture spectra for the model. Initially, we measure the spectra of individual components under different concentrations and temperatures. Subsequently, mixed spectral samples are generated by combining the measured spectra of the individual components. This approach simplifies the spectral measurement process while preserving accuracy. The particle swarm optimization support vector machine (PSO-SVM) algorithm is leveraged, providing a reliable foundation for the continuous and synchronous measurement of NH3 and NO. Upon testing, the PSO-SVM demonstrates average relative errors of 4.0 % and 0.8 % for NH3 and NO concentrations, respectively. The corresponding measurement precision is 0.05 ppm for NH3 and 0.42 ppm for NO, better than the conventional integral absorbance method. The minimum detection limit (MDL) for NH3 is 16.1 ppb at an average time of 50 s, while for NO, it is 38.4 ppb at an average time of 71 s. The methodology of this paper is expected to play an important role in reducing the influence of interfering components and improving the accuracy of field measurements.