Abstract

A method using ultrahigh-performance liquid chromatography in combination with high-resolution time-of-flight mass spectrometry was developed for simultaneous identification and determination of the active ingredients (cetylpyridinium chloride, benzydamine, benzocaine, lidocaine, and tetracaine) in Septolete, Calgel, and Novosept Forte preparations. Analytes were identified using retention times, exact masses of ions, and agreement of isotopic distribution patterns (mSigma). The detection limits and limits of quantitation were 0.001 – 0.005 and 0.005 – 0.01 ng/mL, respectively, for all studied analytes. The ranges of determined contents were 0.01 – 50 and 0.005 – 10 ng/mL. The method was verified using actual preparations. The relative standard deviations of the analytical results were <0.05.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.