Abstract

Nonlinear optical microscopy technique has unique advantages in tissue imaging, such as enhanced contrast, high resolution, and label-free deep optical sectioning capabilities. Nonlinear optical microscopy also has multiple imaging modalities, corresponding to various components in biological tissues. Unfortunately, its wide applications are hindered due to the lack of broadly tunable femtosecond sources designed for driving multimodalities simultaneously. To solve this challenge, we propose a new wavelength conversion approach—self-phase modulation (SPM) enabled spectral selection, dubbed as SESS. The SESS employs SPM to broaden the input spectrum in a short fiber, and the broadened spectrum features well-isolated spectral lobes. Using the suitable optical filters to select the outermost spectral lobes produces nearly transform-limited femtosecond pulses. In this work, we demonstrate a fiber-optic SESS source for multimodal nonlinear optical microscopy. Based on a 43-MHz Yb-fiber laser, this SESS source can emit 990-nm, 84-fs pulses with >5-nJ energy and ~84-fs pulse duration; it can also produce 1110-nm, 48-fs pulses with 15-nJ energy. The 990-nm pulses are used to drive two-photon excitation fluorescence of many important fluorophores and second-harmonic generation microscopy, which, combined with image splicing technology, enables us to obtain a large field of view image of the gastric tissue. We also employ the 1110-nm pulses to drive simultaneous label-free autofluorescence-multiharmonic microscopy for multimodal imaging of gastric tissue. Two-photon excitation fluorescence, three-photon excitation fluorescence, second-harmonic generation and third-harmonic generation signals of gastric tissue are simultaneously excited efficiently. Such a multimodal nonlinear optical microscopy driven by SESS sources becomes a powerful tool in biomedical imaging.

Highlights

  • Schematic setup of the nonlinear optical microscopy driven by SESS

  • Black curve: calculated from the transform-limited pulses allowed by the amplified pulse spectrum

  • Spectrum broadening with coupled energy of 44nJ, spectrum and autocorrelation trace of the filtered pulses at 990nm. (a) Broadened spectrum. (b) Autocorrelation trace

Read more

Summary

Introduction

Schematic setup of the nonlinear optical microscopy driven by SESS. ISO: isolator, LD: laser diode, WDM: wavelength-division multiplexing, Amp: amplifier, HWP: half-wave plate, PBS: polarization beam splitter, L: lens, LPF: long pass filter, NLOM: nonlinear optical microscopy. Spectrum and autocorrelation trace of the amplified pulse. Black curve: calculated from the transform-limited pulses allowed by the amplified pulse spectrum.

Results
Conclusion

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.