Abstract
In complex cases of drug-resistant focal epilepsy, the precise localization of the epileptogenic zone requires simultaneous implantation of depth and subdural grid electrodes. This study describes a new simple frame-assisted method that facilitates the simultaneous placement of both types of intracranial electrodes. Ten consecutive patients were evaluated and divided into two groups. Group A included patients with simultaneous frame-assisted placement of depth and subdural grid electrodes. In group B, depth electrodes were implanted stereotactically; grid electrodes were implanted in a separate surgery. The placement of the subdural grid was accurate as individually designed by the epileptologists in all five patients from group A. In group B, one patient showed a slight and another one a significant deviation of the subdural grid position postoperatively. The mean surgical time in group A was shorter (280±62 minutes) compared with the mean duration of the surgical procedures in group B (336±51 minutes). The frame-assisted placement of subdural grid electrodes facilitates the surgical procedure for invasive video-electroencephalography monitoring in complex cases of drug-resistant focal epilepsy in which a combination of depth electrodes and subdural grid electrodes is needed, by reducing the surgical time and guaranteeing highly accurate electrode localizations.