Abstract
A reverse phase high performance liquid chromatographic method is developed for the simultaneous determination of metformin hydrochloride and repaglinide. Chromatography was carried out at ambient temperature and separation of these drugs was achieved on neosphere C18 column (150 x 4.6 mm i.d, 3.5 mcgm) as stationary phase with a mobile phase comprising of methanol: 0.05 M acetate buffer (pH 3.5) in ratio of (80:20 V/V) at flow rate 0.8 mL/min. The detection wavelength for metformin hydrochloride and repaglinide was 242 nm. The retention times for metformin hydrochloride and repaglinide were 1.8 0.2 min and 8.9 0.2 min respectively. The linearity of metformin hydrochloride and repaglinide was in the range of 2-10 mcg/mL and 5-25 mcg/mL respectively. The recovery was calculated by standard addition method. The proposed method was found to be suitable for simultaneous determination of metformin hydrochloride and repaglinide.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.