Abstract

BackgroundA new, validated, and selective RP-HPLC technique was established for quantitative estimation of Dicyclomine HCl and Simethicone in the pharmaceutical oral liquid drop formulations. The chromatographic conditions were adjusted using Luna C18 (25 cm × 0.46 cm, 5 μm) column, water-methanol mixture (80:20, v/v) as solvent system and pH adjustment up to 7.4 using orthophosphoric acid. The absorbance was observed at 289 nm λmax injecting 20 μl sample solution and maintain the ambient temperature (30 °C) with 1 ml per min flow rate.ResultsThe retention times of Dicyclomine HCl and Simethicone were determined 2.962 and 4.091 min, respectively. The developed analytical technique was validated for accuracy, precision, linearity, specificity, sensitivity, ruggedness, and robustness as per ICH guidelines. The LOD was found to be 0.72 and 0.57 μg per ml for Dicyclomine HCl and Simethicone, respectively. But, LOQ was 2.19 and 1.73 μg per ml, respectively.ConclusionsThis validated method showed good precision (RSD% < 1) with acceptable linearity (≥ 0.999). Intra- and inter-day relative RSD of retention times and AUC (area under curve) were found to be less than 2.0%. The method was also significantly useful as economic technique for simultaneous quantitative determination of Dicyclomine HCl and Simethicone in the bulk and pharmaceutical formulation.

Highlights

  • A new, validated, and selective Reverse phase high performance liquid chromatography (RP-HPLC) technique was established for quantitative estimation of Dicyclomine HCl and Simethicone in the pharmaceutical oral liquid drop formulations

  • Several RP-HPLC methods were availed for quantitative determination of Dicyclomine hydrochloride (DIC) and SIM individually in pharmaceutical dosages forms [9– 21]

  • An oral liquid drop formulation (MeftalSpas Drops manufactured by Blue Cross Laboratories Ltd.) used for the analysis was obtained from market labeled with 10 mg/ml dicyclomine hydrochloride and 40 mg/ml simethicone in the each unit (Fig. 3)

Read more

Summary

Results

The retention times of Dicyclomine HCl and Simethicone were determined 2.962 and 4.091 min, respectively. The developed analytical technique was validated for accuracy, precision, linearity, specificity, sensitivity, ruggedness, and robustness as per ICH guidelines. The LOD was found to be 0.72 and 0.57 μg per ml for Dicyclomine HCl and Simethicone, respectively. LOQ was 2.19 and 1.73 μg per ml, respectively

Conclusions
Background
Methods
Funding Not applicable
Conclusion
Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call