Abstract

A method based on accelerated solvent extraction-ion chromatography (ASE-IC) was developed for the simultaneous determination of trivalent chromium (Cr(III)) and hexavalent chromium (Cr(VI)) in plastic samples. The accelerated solvent extraction was employed as the pretreatment method for the simultaneous extraction of the Cr(III) and Cr(VI) from the samples. Cr(III) and Cr(VI) were derivatized with 2,6-pyridinedicarboxylic acid (PDCA) and 1,5-diphenyl-carbazide (DPC), and detected by an ultraviolet-visible (UV-Vis) detector at UV and visible wavelengths, respectively. The results showed that the limits of detection for Cr(III) and Cr(VI) were 5.0 microg/L and 0.5 microg/L and the good linearities of the calibration curves for them were in the ranges of 50 - 1 000 microg/L (r2 = 0.9994) and 5.0 - 100 microg/L (r2 = 0.9998), respectively. The recoveries were between 90.7% and 101.1% with the relative standard deviations (RSDs) of 1.7% -4.4% for Cr(III) and Cr(VI). The method is sensitive, reproducible and adaptable to the simultaneous determination of Cr(III) and Cr(VI) in the plastic samples.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.