Abstract

Analytical procedures for the determination of tramadol (T), O-desmethyltramadol (ODT), and N-desmethyltramadol (NDT) in human urine have been developed and validated using gas chromatography-mass spectrometry (GC/MS). Sample preparation involved liquid-liquid extraction with methyl-tert-butyl ether (MTBE) and followed by back extraction with 0.1 M hydrochloric acid. Proadifen (SKF525A) was selected as internal standard (IS). Extraction efficiencies of T, ODT and NDT were 102.12, 101.30, and 98.21%, respectively. The calibration curves were linear (r(2)>0.99) in the concentration range 10-1000 ng/mL for all compounds. Limits of quantification (LOQ) were 10, 10 and 20 ng/mL for T, ODT and NDT, respectively. Intra-assay precision was within 1.29-6.48% and inter-assay precision was within 1.28-6.84% for T, ODT and NDT. Intra-assay accuracy was within 91.79-106.89% for all analytes. This method detected urine concentrations of T, ODT and NDT in six healthy volunteers for 7 days after administration of 50 mg oral doses of tramadol.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.