Abstract

Background: 1,3,5-trinitroperhydro-1,3,5-triazine (RDX) and octahydro-1,3,5,7-tetranitro-1,3,5,7-tetrazocine (HMX) can cause serious toxicity problems in humans and animals, but direct analyses of RDX and HMX in biological samples are very limited. A rapid and efficient liquid chromatography-electrospray quadrupole linear ion trap mass spectrometry (LC-MS/MS) method suitable for the simultaneous determination of RDX and HMX in rat plasma after intravenous administration of two nitramine compound mixed solutions has been developed. Methods: Plasma samples were pretreated with one-step protein precipitation, the plasma consumption is as low as 100 μl. RDX, HMX, and internal standard mycophenolic acid were eluted for 8.0 min on a reversed-phase C18 analytical column with a water/acetonitrile mixture as the mobile phase. An electrospray ionization (ESI) source was applied and operated in negative ion mode. The optimized mass transition ion pairs (m/z) monitored for RDX, HMX, and internal standard mycophenolic acid were m/z 284.1→61.7, m/z 331.0→108.8, and m/z 319.2→191.1, respectively. Results: The detection ranges of both RDX and HMX in plasma were 5.00–200.00 ng⋅ml−1 with an LOD of 1.00 ng⋅ml−1. The extraction recoveries of RDX and HMX were 60.04 ± 4.18% and 79.57 ± 3.35%, respectively. The precision and accuracy met the requirements, and the method was stable under all tested conditions. Conclusion: The present method is miniaturized, effective, portable, rapid and can be easily used for simultaneous quantification of RDX and HMX in rat plasma.

Highlights

  • Our preliminary findings during the method development showed that the electrospray source (ESI) was determined to be more sensitive to nitramines than APCI, and electrospray ionization (ESI) was chosen for the ionization of the analytes

  • Adduct ion spectra of [MRDX + NO3]- and [MHMX + Cl]- showed the fragment ions of RDX at m/z 61.9 and that of HMX at m/z 108.8 (Figure 2), which were present in the highest abundance and were chosen for the multiple reaction monitoring (MRM) acquisition of RDX and HMX

  • The one-step protein precipitation had a consumption of plasma volumes as low as 100 μL and reduced the pretreatment time, proving the pretreatment method is the most advanced up to now

Read more

Summary

Methods

Plasma samples were pretreated with one-step protein precipitation, the plasma consumption is as low as 100 μl. RDX, HMX, and internal standard mycophenolic acid were eluted for 8.0 min on a reversed-phase C18 analytical column with a water/acetonitrile mixture as the mobile phase. An electrospray ionization (ESI) source was applied and operated in negative ion mode. The optimized mass transition ion pairs (m/z) monitored for RDX, HMX, and internal standard mycophenolic acid were m/z 284.1→61.7, m/z 331.0→108.8, and m/z 319.2→191.1, respectively

Results
INTRODUCTION
MATERIALS AND METHODS
RESULTS AND DISCUSSION
CONCLUSION
ETHICS STATEMENT
Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call