Abstract
A simple, rapid, and precise RP-HPTLC method for analysis of Prednisolone acetate and Moxifloxacin hydrochloride in their eye drop dosage forms has been developed and validated. Chromatography was performed on silica gel 60 RP-18F254S plates with Methanol:Water:Triethylamine 7:3:0.3 (v/v) as mobile phase. Detection was performed at 274 nm. The Rf values for Prednisolone acetate and Moxifloxacin hydrochloride were found to be 0.50 ± 0.02 and 0.72 ± 0.02, respectively. Regression plots revealed good linear relationships in the concentration ranges 600–3600 ng/band for Prednisolone acetate and 300–1800 ng/band for Moxifloxacin hydrochloride. When accuracy was checked by conducting recovery studies the % recoveries were ranging from 100.97% to 102.03% (Prednisolone acetate) and 100.49% to 101.25% (Moxifloxacin hydrochloride), respectively. The amount of Prednisolone acetate and Moxifloxacin hydrochloride estimated in marketed formulation were 99.22% and 101.07%, respectively.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: Journal of Liquid Chromatography & Related Technologies
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.