Abstract

A method based on high performance liquid chromatography with a coulometric electrode array system (HPLC‐coulometric electrode array) using C18 column has been developed for the simultaneous determination of norepinephrine (NE), epinephrine (E), l‐3,4‐dihydroxyphenylalanine (l‐DOPA), p‐tyrosine (p‐TYR), dopamine (DA), m‐tyrosine (m‐TYR), 5‐hydroxytryptamine (5‐HT), homovanillic acid (HVA), and 5‐hydroxyindoleacetic acid (5‐HIAA) in mice brain. The chromatography was performed using a C18 column (250 mm×4.6 mm i.d. and 5 µm) with sodium acetate buffer (pH 5.0, 0.05 M) and methanol as the mobile phase. Elution of analytes was carried out at a flow rate of 1.0 ml/min. The nine compounds were monitored using an ESA electrochemical detector. Potentials of three electrodes in series were set at 200, 500, and 700 mV, respectively. Optimization of the pH of the mobile phase and the proportion of methanol were also considered. The minimal detection limits were 2–8 ng/ml. Linear (r=0.99) detector performances were observed within a range of 10∼2000 ng/ml. Recoveries for the nine compounds in spiked samples were over 90% and the relative standard deviations (RSD) were less than 4.0%.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.