Abstract
The simultaneous determination of metronidazole benzoate (MB), methylparaben (MP), and propylparaben (PP) in an oral suspension formulation was developed using high-performance liquid chromatography (HPLC). The method was developed using a Novapak C18 (3.9 × 150 mm, 4 μm) column, methanol-water (50:50, v/v) as the mobile phase and an ultraviolet (UV) detector at 254 nm. The peak area response versus concentration was linear in a concentration range from 40 to 400 μg/ml of MB, 0.8 to 8.0 μg/ml of MP, and 0.2 to 2.0 μg of PP. The correlation coefficients were 0.9997 for MB, 0.9987 for MP, and 0.9983 for PP, with relative standard errors of 1.12%, 1.28%, and 1.67%, respectively.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.