Abstract

A high performance liquid chromatographic method was developed for simultaneous determination of 5 whitening ingredients: magnesium ascorbyl phosphate, ascorbyl glucoside, kojic acid, arbutin and hydroquinone decomposed from arbutin in cosmetics. Samples were extracted with 0.05 M KH2PO4 buffer solution (pH 2.5) and analyzed using a Cosmosil 5 C18-AR-II column. A mixture of 0.05 M KH2PO4 buffer solution (pH 2.5) and methanol (99:1, v/v) was used as mobile phase. The UV detector was set at 280 nm. Pyridoxine was used as an internal standard. The related coefficients, R2, of regression equations of the 5 standard curves were 0.9998-1.0000. The relative standard deviations of the 5 ingredients for intraday and interday analysis were less than 2.4%. The average recoveries of these 5 ingredients spiked in sample ranged from 93.5% to 103.3%. The relative standard deviations of average recoveries were less than 1.3%. The limits of quantitation in cosmetics were 80.0, 20.0, 3.0, 15.0 and 10.0 μg/mL for magnesium ascorbyl phosphate, ascorbyl glucoside, kojic acid, arbutin and hydroquinone, respectively.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.