Abstract
A high-performance liquid chromatography—diode-array detection method was developed and validated to determine simultaneously eleven major alkaloids in Corydalis decumbens (Thunb.) Pers. The alkaloids detected were corlumidine, protopine, coptisine, tetrahydrojatrorrhizine, palmatine, berberine, sanguinarine, papaverine hydrochloride, tetrahydropalmatine, bicuculline, and corydaline. Chromatographic separation was achieved using a C-18 column with a mobile phase composed of A (0.2% acetic acid solution, adjusted with triethylamine to pH 5.0) and B (acetonitrile), with stepwise gradient elution. Ultraviolet diode-array detection was used; chromatograms were examined at the wavelength of 280 nm. The regression equations showed a good linear relationship between the peak area of each marker and concentration (r = 0.9994–0.9999). The recovery values ranged between 93.66% and 100.54%. The method was fully validated with respect to detection and quantification limits, precision, reproducibility, and accuracy. The described high-performance liquid chromatography (HPLC) method was successfully used for the differentiation and quantification of the eleven major alkaloids in C. decumbens (Thunb.) Pers. and can be considered an effective procedure for the analyses of this important class of natural compounds.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.