Abstract
The aim of the present study was to establish a liquid chromatography‐tandem mass spectrometric (LC‐MS/MS) method for the simultaneous determination of di(2‐ethylhexyl) phthalate (DEHP), mono(2‐ethylhexyl)phthalate (MEHP), and phthalic acid (PA). In the proposed method, the limits of detection of DEHP, MEHP, and PA were 5, 0.5, and 1 ng/mL, respectively, and the limits of quantification with standard solutions were 20, 2, and 5 ng/mL, respectively. Intra‐ and interday assays showed good accuracy and repeatability. The recoveries of DEHP, MEHP, and PA from respective extraction solvents ranged from 98.9 to 104.2% (relative standard deviation was below 10.3%). DEHP and its breakdown products migrating from gamma‐ray irradiated polyvinyl chloride (PVC) sheets were determined simultaneously since DEHP is easily eluted from PVC medical devices. DEHP migration was noted from both gamma‐ray irradiated and control PVC sheets. Compared with the migration from the control PVC sheet, MEHP showed significant migration from the gamma‐ray irradiated PVC sheet. In contrast, PA migration was noted only from the gamma‐ray irradiated PVC sheet.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: Journal of Liquid Chromatography & Related Technologies
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.