Abstract
A novel method for simultaneous determination of cortisol and prednisolone in body fluids has been developed in this paper. Three-way data recorded by high-performance liquid chromatography with a diode array detector (HPLC-DAD) have been analyzed by second-order calibration based on the alternating trilinear decomposition (ATLD) algorithm. The chemometric methodology selected exploits the second-order advantage of the three-way data arrays, which allows one to obtain concentrations of individual calibrated analytes even in the presence of interferences not present in the calibration samples (e.g. background in urine or plasma). It was applied to simultaneous determination of cortisol and prednisolone in both plasma and urine samples. Though the chromatographic and spectral peaks of the analytes were heavily overlapped and interferents coeluted with the compounds studied, good recoveries of the analytes could be obtained with HPLC-DAD coupled with second-order calibration based on ATLD. Sample preparation was based on solvent extraction (SE), and quantification can be carried out with simple mobile phase. The time required for the quantification process is shorter than other methods.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.