Abstract
A sensitive and rapid method based on ultra-performance liquid chromatography coupled with tandem mass spectrometry (UPLC-MS/MS) was developed and validated for the simultaneous determination of blonanserin, its major active metabolite (N-deethyl form) and other three metabolites (N-oxide form, Ethylenediamine form and Carboxylate form) in human plasma. Plasma samples were pre-purified by solid-phase extraction (SPE) and analyzed using a gradient chromatographic separation over an Acquity UPLC CSH C18 column. The mobile phase consisted of acetonitrile-water containing 5mM ammonium formate and 0.1% formic acid at a flow rate of 0.5mL/min. Positive electrospray ionization was employed as the ionization source in the multiple reaction monitoring (MRM) mode. The analysis time was about 3.5min. The method was fully validated over the concentration range of 0.01-1ng/mL for all analytes. The lower limit of quantification (LLOQ) was 0.01ng/mL. Inter- and intra-batch precision was less than 15% and the accuracy was within 85-115%. The mean extraction recoveries of all analytes at two concentration levels were consistent. Selectivity, matrix effect and stability were also validated. The method was applied to the pharmacokinetic study of blonanserin in Chinese healthy subjects.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.