Abstract

A headspace gas chromatography-mass spectrometry (HS-GC-MS) method is presented for the simultaneous determination of benzoic acid (BA) and sorbic acid (SoA) in different types of non-alcoholic beverages. Sensitive and reliable results were achieved together with minimising consumption of reagents and samples. Salicylic acid (SalA) was used as internal standard (IS). It was necessary to derivatise BA, SoA and SalA to their methyl esters for HS-GC-MS measurement and extensive optimisation studies for in-vial derivatisation were carried out on the temperature, incubation time, injection time of the loopless HS, as well as on the concentration of sulphuric acid used as a catalyst. Validation studies carried out under optimum conditions after mixing 50 µL of sample and IS solutions with 200 µL of 4.5 M sulphuric acid in 22 mL HS vials revealed that the developed method was both very precise (relative standard deviation < 5%) and accurate (average recovery%: 101.0% for BA and 100.4% for SoA). The validated method was applied to a wide range of beverage types and the results compared with the relevant regulation and product label declarations.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.