Abstract

A simple, rapid and accurate method for simultaneous determination of amoxycillin and clavulanic acid using HPLC with β-cyclodextrin stationary phase was developed. It involves the use of tetraethylammonium acetate (TEAA) as an additive reagent, methanol-buffer solution (pH 4.5) (35:65; v/v) as the mobile phase, detection at 225 nm and chromatogram within 12 min. Linearity and precision of the internal standard method have been obtained. Recoveries ranged from 99.25 to 105.63% for amoxycillin in the synthetic mixture. For clavulanic acid it was from 99.50 to 101.64%. This method is convenient and reproducible for analyses of these two components in different dosage forms.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.