Abstract
A highly sensitive method was investigated for the simultaneous determination of acetaminophen (AC) and dopamine (DA) using single wall carbon nanotubes modified carbon–ceramic electrode (SWCNT/CCE). The SWCNT/CCE displayed excellent electrochemical catalytic activities towards the oxidation of AC and DA. Under optimized experimental conditions in differential pulse voltammetry technique, AC and DA gave linear response over the ranges 0.2–100.0μM (R2=0.996) and 0.4–150.0μM (R2=0.999), respectively. The detection limits (S/N=3) were found to be 0.12μM for AC and 0.22μM for DA. The present method was applied to the determination of AC and DA in some commercial pharmaceutical samples.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.