Abstract

A sensitive and selective high-performance liquid chromatography-tandam mass spectrometry (LC-MS/MS) method was developed and validated for the simultaneous quantification of sildenafil and its metabolite N-desmethyl sildenafil in human plasma. Sildenafil-d8 was used as an internal standard. The analytes were extracted by precipitation extraction and chromatographed on a C18 column using mobile phase A of water (containing 0.1% formic acid) and mobile phase B of acetonitrile (containing 0.1% formic acid) with gradient elution. Quantification was done using multiple reaction monitoring mode to monitor the precursor-to-product ion transitions of m/z 475.4 → m/z 283.3 for sildenafil, m/z 461.4 → m/z 283.2 for N-desmethyl sildenafil and m/z 483.3 → m/z 108.1 for IS in positive ionization mode. The calibration curve was established over the range of 2.00-1,000 ng/ml and the correlation coefficient was >0.99. The intra-day and inter-day relative standard deviations were <6.5% for sildenafil and 6.3% for N-desmethyl sildenafil respectively. Accuracy determinaed at four concentrations was 86.50-105.67% for sildenafil and 96.83-114.40% for N-desmethyl sildenafil. This method was successfully applied to a pharmacokinetic description of sildenafil and the effect of food intake on the pharmacokinetics of sildenafil was also demonstrated in healthy Chinese volunteers.