Abstract

A pleural window communicating between bilateral pleural cavities is a serious condition in patients with pneumothorax, allowing air to leak from the affected lung into the contralateral pleural cavity and resulting in bilateral spontaneous pneumothorax. We treated a patient with a history of right-sided bullectomy for simultaneous bilateral spontaneous pneumothorax that subsequently recurred. A pleural window (1 cm long) was detected in the mid-mediastinum, and direct suture closure with localized pleural abrasion using argon beam coagulation on the circumference of the lesion was performed at video-assisted thoracoscopic surgery.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.