Abstract

Internal transport barriers have been demonstrated to exist also under conditions with T(e) approximately T(i) approximately 10 keV and predominant electron heating of the tokamak core region. Central electron cyclotron heating was added to neutral beam injection-heated ASDEX Upgrade discharges with a preexisting internal transport barrier, established through programmed current ramping leading to shear reversal. Compared to a reference internal transport barrier discharge without electron cyclotron resonance heating, the electron heat conductivity in the barrier region was found not to increase, in spite of a fivefold increase in electron heat flux, and also angular momentum and ion energy transport did not deteriorate.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.