Abstract

A selective and simple HPLC method was developed for ibuprofen (IBF) and pamabrom (PAMB) from in bulk and drug product using the same conditions, which was operated on a reverse phase (C18 column) with water (60 %) and acetonitrile (40 %.) solutions at a flow rate of 1.0 mL/min. IBF was detected at 2.6 min and PAMB at 8.0 min, respectively at 254 nm. The correlation coefficient (R2) for IBF was 0.9999 and that of PAMB was 0.9998 in 125–2000 and 63–100 μg/mL, respectively. Intraday precision showed less than 1.0 % RSD. This method was validated in an aspect of linearity, precision, accuracy, limit of detection and limit of quantitation. This method was suggested to analysis the fixed dose combination tablet of IBF and PAMB.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.