Abstract
A novel, simple and sensitive method was developed for the simultaneous determination of eight phenolic environmental estrogens in blood by using the dispersive micro-solid-phase extraction (d-µ-SPE) procedure combined with ultra-fast liquid chromatography–tandem quadrupole mass spectrometry (UFLC–MS/MS). The excellent nanomaterials tetraethylenepentamine-functionalized magnetic polymer was used as an adsorbent, and the main factors affecting the extraction efficiency were investigated in detail. All target compounds showed good linearities in the tested range with correlation coefficients (r) higher than 0.999. The mean recoveries were in the range of 85.0–105.0%. The intra-day and inter-day relative standard deviations (RSDs) were lower than 4.9% and 5.2%, respectively. The limits of quantification for the eight phenolic environmental estrogens were between 0.075 and 0.42µgL−1. The developed method can be applied to the routine analyses for the determination of the eight phenolic environmental estrogens in blood samples.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.