Abstract
Eight novice operators and eight expert surgeons were randomly assigned to one of three simulators. Each participant performed two exercises using a simulator and then using a surgical robot. The primary outcome of this study is performance assessed by time and GEARS score. Participants were randomly assigned to one of three simulators. Time to perform the suturing exercise (novices vs. experts) was significantly different for all 3 simulators. Using the da Vinci robot, peg transfer showed no significant difference between novices and experts and all participants combined (mean time novice 2.00, expert 2.21, p = 0.920). The suture exercise had significant differences in each group and all participants combined (novice 3.54, expert 1.90, p = 0.001). ANOVA showed p-Values for suturing (novice 0.523, expert 0.123) and peg transfer (novice 0.742, expert 0.131) are not significantly different. GEARS scores were different (p < 0.05) for novices and experts. Training with simulators of varying fidelity result in similar performance using the da Vinci robot. A dry box simulator may be as effective as a virtual reality simulator for training. Further studies are needed to validate these results.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.