Abstract

The pump height (ΔH) of liquid A356 alloy by the plane induction electromagnetic pump supplying liquid aluminum alloys during casting was measured, and the experimental values agreed with 3D simulation results. It was found that the relationship between ΔH and frequency was relevant with structural design parameters, and the increase of ΔH versus frequency started to deviate from linearity when the width of the pump ditch (b) was higher than that of the iron core (W). ΔH was found to be always proportional to the square of the current and irrelevant with frequency and structural design parameters. It was also found that ΔH decreased significantly with the magnetic gap and increased with W and the thickness of the iron core, while ΔH was not affected by the polar distance. In addition, ΔH increased first rapidly and later slowly with b till the maximum was reached, after which ΔH started to decrease slowly with b.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.