Abstract

The temperature distribution is an important aspect of any brake pad composite material. The braking temperature affects the performance and efficiency of any brake pad composite material. It is difficult to measure the interface temperature between the brake pad and disc by thermocouples or infrared thermal sensors during braking. This work investigates the temperature distribution of a ceramic composite brake pad material by the transient thermal analysis method. The transient thermal approach method helps to visualize the interface temperature through simulation. Also, it provides pin temperature at a distance of 4 mm and 6 mm away from the disc surface to observe the temperature distribution of the brake pad. The experimental values of the temperature of the pin at 4 mm and 6 mm away from the disc are collected from the literature and compared with the predicted temperature through simulation. It is found that there is a close agreement between the predicted and experimental temperature values.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.