Abstract

The subject of this study is the simulation of low-frequency transients (such as acceleration, deceleration) of different open cycle gas turbine types. Special attention is paid to the correct calculation of the effects of heat transfer between process gas and solid structure. Correcting equations for these effects are developed and the transient properties of each component are then evolved from the static ones with these equations. It is shown that the heat transfer effects alter significantly the surge margin of the compressor. Simulation model includes intercooler and recuperation. The programming language is CSMP.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.