Abstract
The aim of this study is to design a solar off-grid PV system to supply the required electricity for a residential unit. A simulation model by MATLAB is used to size the PV system. The solar PV system is simulated with the case of maximum solar radiation on a sunny day. The results show that the average daily load requirement of the selected residential unit is 36 kWh/day. This load requirement can be meet by using an array of 44 solar panels. During the day time, the PV system supplies the desired 12.4 kWh of energy. During the night time, a battery storage system of 23.6 kWh (48V, 350 Ah) is used to meet the night load.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.