Abstract

To study fire after the mechanical performance of steel girder node special-shaped concrete-filled steel tube column, based on standard ISO - 834 litres of cooling curve, the node temperature field model was established based on finite element software ABAQUS, the compute nodes in the overall uniform temperature field under fire as a result, the reasonable choice of fire after the steel and concrete constitutive model, the temperature field results into the node stress model, considering the factors that influence the whole effect of fire loading in low cycle, the nodes of the finite element model, and contrast analysis of the temperature after the fire of the node and hysteretic performance and ultimate bearing capacity. The results show that the failure modes of special-shaped CFST column-steel beam joints at room temperature and after fire are the same, and the ultimate bearing capacity of the joints after fire decreases significantly by 14.88% compared with that at room temperature.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.