Abstract

Pulsed eddy current (PEC) detection technology has gained attention in the research and development of the non-destructive testing (NDT). In contrast to the conventional eddy current testing method, the PEC detection technology uses pulsed excitation that is characterized by the richness of frequency. So when the inner corrosion of the low-carbon steel pipeline is detected by the PEC technology, the insulation and protective layers outside the pipeline needn't be dismantled. In this paper, the relationship between corrosion size and the signal of PEC is simulated. The simulation results will provide reference for the quantitative detection of the corrosion.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.