Abstract
A pulse-dilation framing tube with large aperture short magnetic lens is simulated by using Monte Carlo method. The photo-cathode (PC) sensitive diameter is 60 mm, and the image ratio is 2:1. While a -3.15 kV dc voltage overlap by an excitation pulse with gradient of 3 V/ps are applied on PC, a gating pulse with width of 225 ps and amplitude of -1.3 kV plus a −100 V dc bias are for the microchannel plate (MCP), the temporal resolution and spatial resolution are 7.8 ps, 11 lp/mm, respectively. The electron beam temporal magnification factor is about 10.3. The relationship between the spatial resolution and the PC electron beam emitting point is obtained. The variation of the temporal magnification factor and temporal resolution with the PC excitation pulse gradient is also given. Furthermore, the connection between the spatial resolution and the PC excitation pulse gradient is acquired.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.