Abstract
The Nested Thermal Envelope Design™ is an innovative low-energy house design that incorporates two thermal envelopes to create a core and perimeter zone. The perimeter acts as a thermal buffer zone, where heat loss from the core and solar gain in the perimeter are recovered to the core via an inter-zone heat pump. To optimize heat recovery from the perimeter and minimize temperature stratification, a complete loop is formed around the core living space, through which air may flow in a convective loop. A simplified convective loop was modelled with a commercial computational fluid dynamics software package. The results show that the convective loop distributes solar gains and reduces temperature stratification in the perimeter. The location of the heat pump in the convective loop was found to affect the heat pump’s coefficient of performance by up to 21%.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.