Abstract
The presented post-test calculations of the test PACOS Px2.2 performed at Ruhr-Universität Bochum (RUB) regard the predictability of the containment spray system’s effect using the lumped parameter codes ASTEC and COCOSYS. The focus of the calculations is set on the decrease of temperature and pressure in case of severe accident scenarios in light water reactor containments. The comparison of the simulation results to experimental data shows, that pressure and temperature during spraying can be simulated satisfactorily with ASTEC and COCOSYS. While calculating the results of the pressure with high agreement to the experiment, both codes underestimate the temperature more and more with increasing distance along the spray path, as the increasing temperature caused by a moving steam cushion is underestimated. The steam cushion is caused by spray induced convection pushing the warmer atmosphere of the upper test facility compartments into the cooler lower compartments. The temperature increase in the lower zones resulting from the establishing flows cannot be simulated properly, as both codes are not fully capable of calculating the occurring forces between dynamic atmosphere and droplet surface.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.