Abstract

This study evaluated the feasibility of using soft contact lenses (CLs) with an opaque centre to induce absolute central scotomas that move with the eye. We examined the geometrical optics prediction that scotoma size will vary with the size of the CL's opaque centre and with ocular pupil size. We also tested the hypothesis that high environmental light levels will ensure that the ocular pupil will remain small enough, even with opaque centre CLs, to generate absolute scotomas representative of those experienced by patients with age-related macular disease. Using an Octopus 900 Perimeter ( www.Haag-Streit.com), kinetic visual fields (VFs) were measured in five normally-sighted subjects using a V4e Goldmann target with CLs that had central opaque areas with diameters of 2.8, 3.0, and 3.2mm. To control pupil size, VFs were measured with background perimeter bowl luminances of 10, 585, and 1155cdm-2 . Subjects attempted to (i) fixate the bowl centre; and (ii) place the scotoma edge at the bowl fixation target (eccentric viewing). As predicted, there was a direct relationship between scotoma size and both luminance level and diameter of the opacity. Mean scotoma diameters were 0°, 17.6° and 22°, for the low, medium and high bowl luminances, respectively. Scotoma size was determined primarily by the difference between the diameters of CL opacity and the entrance pupil of the eye and the axial separation between them, and between-subject differences in pupil diameters contributed most to the between-subject variability in scotoma diameter at each light level (SD: 6.01°). Scotoma displacement during eccentric fixation confirmed the gaze-contingent characteristics of this experimental model. It is possible to induce a gaze-contingent absolute scotoma and hence mimic central vision loss using centrally-opaque CLs provided that the CL opacity is larger than the entrance pupil of the eye. This simulation tool will, therefore, be ineffective at low environmental light levels (as shown previously) if the entrance pupil of the eye is larger than the CL opacity.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.