Abstract
The second part of the study on 5G NR network positioning technology with meter accuracy modeling is devoted to the procedures for range-difference measurements processing based on configured PRS positioning reference signals with the resulting estimate of the user equipment coordinates based on observed time difference of arrival (OTDOA) of the signals. The software implementation of the procedures for PRS signals primary and secondary processing in the simulation model uses the built-in functions of the 5G Toolbox extension package of the special MATLAB software. The assessment of the positioning accuracy of user devices in 5G NR networks using simulation modeling in the FR1 range shows that the accuracy of coordinate estimates of less than one meter is achieved when increasing the bandwidth from 50 to 60 MHz with the maximum positioning accuracy in the FR2 band in a channel having a bandwidth of 400 MHz and a sampling rate of 491.52 MHz was 0.2 m.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.