Abstract

In this paper, a theoretical and experimental investigation on HDH evaporation system performance was performed. A fixed size HDH system was constructed, and for the purpose to obtain the optimal operating parameters, a mathematical model was proposed to investigate the effect of the operating parameters on the evaporation rate and specific steam consumption (SSC). The evaporation rate is proportional to three operating parameters. SSC decrease with the increase of heat recovery ratio (HRR) in regenerator. Moreover, the operating parameters of the system were optimized to obtain minimum SSC using the GlobalSearch algorithm. The minimum SSC is 0.338–0.398 kg per kg of evaporated water at different evaporation capacities. And the value of minimum SSC increases with an increase in the evaporation limit. Furthermore, the experimental results were compared with the optimized results, and they are in good agreement. Considering both the evaporation rate and SSC, the recommended operating parameters are: mg = 502.53 kg/h, ml = 3556.93 kg/h, Tlie = 83.59 °C.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.