Abstract

Two control schemes for active and reactive power of a double-fed induction generator with the stator connected direct to the constant frequency, three phase grid are described. First the direct and quadrature rotor current components are generated based on the mathematical model of the machine. The second scheme used a PI controller to generate the rotor current reference components. The principles of both schemes are described in detail in this paper with a strong experimental approach. A complete simulation model is developed and several studies are performed to test its under different conditions. A laboratory test setup consisting of a wound rotor induction machine and driven by a variable speed squirrel cage induction motor is used to validate the control schemes proposed and the simulation results.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.